2009 UNIFORM PLUMBING CODE PDF

adminComment(0)

The advantages of a uniform plumbing code adopted by various local jurisdictions The Uniform Plumbing Code is supported by the American Society of. PDF Drive is your search engine for PDF files. As of today we have Complete copies of the Uniform Plumbing Code as published by the. International. Directory of Listed Plumbing Products for Manufactured Housing and Recreational The daily IAPMO UPC IAPMO UMC (): Uniform Mechanical Code.


2009 Uniform Plumbing Code Pdf

Author:OZELLA MABERY
Language:English, Indonesian, French
Country:Guyana
Genre:Lifestyle
Pages:468
Published (Last):06.03.2016
ISBN:650-1-65315-739-8
ePub File Size:17.87 MB
PDF File Size:12.48 MB
Distribution:Free* [*Registration Required]
Downloads:45504
Uploaded by: CHIA

Complete copies of the Uniform Plumbing Code as published by Uniform Plumbing Code, Standards and amendments – WAC The primary rules governing the processing of the Uniform Plumbing Code and Uniform .. Report on Proposals and Report on Comments in digital Adobe PDF. ASTM A (R) Gray Iron Castings for Valves, Flanges, and Pipe. Uniform Plumbing Code (UPC) - Download as PDF File .pdf), Text File .txt) or read online.

Uniform Plumbing Code Books

The Charles River was a sewer for many, many years, she says. Weve come a long way since then. Frymire isnt convinced. We need to keep more of the storm water out of the sewers, he says. Keep a notebook to track dates and times of conversations with individuals pertaining to your claim.

Save receipts for meals, hotels, toiletries, replacement clothing, prescriptions, etc. Take photos of each room for future reference and insurance claims. This will provide a digital inventory of some visible contents.

If electrical appliances, including televisions and computers are damaged by water, do not turn them back on when power is restored. Beware of scammers offering restoration services. Check references and visit the Restoration Industry Association website www. Wear heavy rubber gloves or work gloves and thick-soled shoes, preferably not tennis shoes.

2009 Uniform Plumbing Code

Wash your hands frequently especially before touching your face or eating. Be careful of muddy water there can be sharp items such as broken glass, nails, etc.

Avoid cross contamination don't wear dirty clothes or shoes to the clean part of the house. Drink lots of water to stay hydrated. Don't use bleach to disinfect since it is corrosive and can react with other substances. Page 2 Exceptions: Add a new Exception to Section The water heater thermostat shall not be considered a control for meeting this provision.

Landings shall be placed at eighteen foot mm intervals. Each ladder shall have a minimum of a six 6 inch mm toe space. A portable ladder may be used for access for Group R Division 3 and 4 and U occupancies.

Permanent exterior ladders providing roof access need not extend closer than eight 8 feet mm to the finish grade. Each ladder rung shall be spaced at a maximum of fourteen 14 inches mm on center.

Each ladder shall have intermediate horizontal landings whenever the ladder height exceeds eighteen feet mm above finished grade. Add a new Section Relief valves located inside a building shall be provided with a drain. Other gas vents shall terminate not less than two 2 feet 0. These documents shall be recorded into the permanent record at the time of installation. Permanent ladders for equipment access need not be provided at parapets or walls less than thirty 30 inches mm in height.

A single-family residence having gas vents twelve 12 inches mm in size or smaller with listed caps shall be permitted to be terminated in accordance with Figure The periodic testing shall be performed in accordance with the procedures referenced in Table by a tester qualified in accordance with those standards.

The certified tester shall leave a copy of their backflow certification on site along with a copy of the certification of each device tested. Gas vents twelve 12 inches mm in size or smaller with listed caps shall be permitted to be terminated in accordance with Figure Potable water supply to carbonators shall be protected by a listed reduced pressure principle backflow preventer as approved by the authority having jurisdiction.

Items 2 through 6 remain unchanged. Cleanouts shall be provided at every ninety 90 degree 1. The terminal end of the drain pipe shall not be threaded. Plastic piping used for drainage waste and vent systems shall be limited to buildings defined as combustible construction by this code. Delete Section The flood level rim of the receptor shall be not less than six 6 inches mm lower than the lowest floor drain. No part of such drain pipe shall be trapped or subject to freezing.

Other than a single dwelling unit served by an individual sewer. Such waste shall discharge through an airgap into a trapped and vented receptor. Page 4. Such floor drains shall be trapped and individually vented. The waste lines from toilets. Gravity Grease interceptors Grease interceptors shall be placed as close as practical to the fixtures served. When any indirect waste piping other than the discharge from the clothes washer is terminated into a washer box. Page 5. The second port shall be permanently connected to the vertical receptor standpipe via a wye branch fitting or a listed multiport clothes washer box may be used.

Written application describing exact operation and anticipated volumes of grease shall be made to the Sanitation Authority Having Jurisdiction to determine the standards for such systems. The clothes washer shall discharge through an air break into the primary receptor standpipe. Special consideration shall be given to every fish. A grease interceptor shall be provided for proper handling of liquid wastes containing grease. Floor sinks shall be installed flush with the finished floor and shall be accessible for cleaning.

Fixtures such as. A grease interceptor as described in these standards shall be installed in any business establishment with kitchen facilities including restaurants. All other indirect waste piping shall discharge into the secondary port through an air gap.

The waste discharge from fixtures and equipment which may contain grease from the businesses set out previously shall be drained through a grease interceptor or grease interceptors. Each fixture discharging into a grease interceptor shall be individually trapped and vented in an approved manner.

For business establishments other than commercial restaurants. The fittings shall be installed in the following manner: A sanitary tee shall be installed at the inlet. Grease interceptors shall be so designed that they will not become air bound.

Page 6. Interceptor covers shall have a minimum opening dimension of twenty 20 inches mm in diameter. Such designs shall be prepared by a Nevada Registered Engineer. Any leakage below this level is cause for rejection. Cleanouts shall be installed in the drainage piping inlet and outlet side of each grease interceptor and the outlet side of each sample box. Interceptors shall not be backfilled until the inspection has been made to verify there are no leaks.

A minimum of one access point into each compartment within the separator shall be provided.

An accessible hose bib shall be located within 25 feet mm of every grease interceptor. A water test shall be applied to the level of the top of the interceptor inlet opening through the outlet opening or discharge side of the sample box.

2009 Uniform Plumbing Code

Multiple business connections to a single interceptor are not permitted. Location of all grease interceptors shall be shown on the approved plans. Each interceptor shall be properly vented with a relief vent located on the outlet side of the interceptor.

Structural calculations to verify its adequacy may be required. Each grease interceptor shall have an approved water seal of not less than two 2 inches Interceptors shall not be more than one size larger than required in Table When grease interceptors are located in areas of pedestrian or vehicle travel. Grease interceptors shall be so located as to be accessible for service without the use of ladders or the removal of bulky equipment.

There shall be adequate access for cleaning all areas of the separator. All waste shall enter the grease interceptor through the inlet pipe. Interceptors shall show no leakage from section seams. Unless approved by the sanitation authority in writing. Separator covers shall be of gas-tight construction.

For situations not covered by Table In addition.

Grease interceptors shall be sized in accordance with Table Each grease interceptor shall serve only one business establishment. Interceptors as described in these standards shall be installed in. An interceptor shall be provided for the proper handling of liquid wastes containing oil of petroleum origin. The waste discharge from fixtures and equipment which may contain sand.

This requirement includes. Submittal of a written application describing the exact facility operation and the types and anticipated volumes of waste to be generated may be required by the building official.

Access covers shall have a minimum opening dimension of twenty 20 inches mm in diameter. The waste line from toilets. A minimum of one 1 access point into each compartment within the separator shall be provided.

Design standards other than those listed above may be acceptable. When separators are located in areas of foot or vehicle traffic. Whenever an existing building has a change in use which requires an interceptor or whenever there is an increase in the total number of drainage fixture units served by an existing interceptor.

An American National Standard

The materials removed from interceptors shall be handled and disposed of in a proper manner in accordance with published health district and sanitation authority requirements. Redwood baffles shall not be used for new or existing interceptors. Any private or public wash rack or slab used for cleaning machinery or machine parts. Illegal dumping of waste into the sewer shall not be allowed.

January/February 2011 Volume 33, Number 1

Abandoned interceptors shall be cleaned and filled as required by Section Page 8. No such collected grease. Separate owners or lessees within a large business or establishment shall require separate interceptors. Any alternate design shall be prepared by a Nevada Registered Engineer and submitted for review and approval by the sanitation authority and the building official.

Structural calculations performed by a Nevada Registered Engineer to verify adequacy may be required. Where the conduit terminates within a building. Combining Storm with Sanitary Drainage. Products listed for such use.Wear heavy rubber gloves or work gloves and thick-soled shoes, preferably not tennis shoes.

Wash your hands frequently especially before touching your face or eating. Abandoned interceptors shall be cleaned and filled as required by Section Chapter 1 Administration.

Permanent exterior ladders providing roof access need not extend closer than eight 8 feet mm to the finish grade.

Those certain documents, [three] copies of each being on file in the Office of the City Clerk, and designated as follows, are adopted byreference and made apart of this Code, to the same effect as if set out herein in full: